20L BVV ECO Rotary Evaporator

★★★★☆ 4.0 135 reviews

US$1,938.46
Price when purchased online
Free shipping Free 30-day returns

Sold and shipped by westerndieselparts.ca
We aim to show you accurate product information. Manufacturers, suppliers and others provide what you see here.
US$1,938.46
Price when purchased online
Free shipping Free 30-day returns

How do you want your item?
You get 30 days free! Choose a plan at checkout.
Shipping
Arrives Sep 26
Free
Pickup
Check nearby
Delivery
Not available

Sold and shipped by westerndieselparts.ca
Free 30-day returns Details

Product details

Management number 250468990 Release Date 2026/09/17 List Price US$1,938.46 Model Number 250468990
Category
20L BVV ECO Rotary Evaporator

10-50L NEO and ECO Rotary Evaporator Diagram

BVV 20L ECO Rotary Evaporator

Unit Specifications:

  • Glass Material: GG-17 High Borosilicate Glass
  • Shelf Material: Aluminum Alloy
  • Pot Material: Stainless Steel, Fully sealing and heating
  • Rotary Bottle Capacity: 20L
  • Collection Bottle Capacity: 20L
  • Rotary Power: 220v-50/60hz
  • Rotary Speed: 20-130rpm
  • Heating Power: 3300w
  • Bath Temperature Control Range: RT+5c-99.9c
  • Digital Temperature Control
  • Temperature Control Accuracy: +/-1C
  • Lifting Mechanism: Electric
  • Dimensions Assembled (LxWxH in.): 42x24x77
  • Weight: 195 LBS

Please note this unit does not come with a plug, as it is designed to be hard-wired into a junction box by a qualified electrician.

”œContinuous Feed” Operating Procedure:

This procedure is the most efficient way to run a rotovap. It will give you the fastest speeds, with minimal heat load to the chiller. This procedure is meant to be a basic starting point for anyone new to using rotovaps. It assumes you are evaporating an ethanol solution for recovery and reuse of the ethanol. Once you have mastered this procedure, you can begin adjusting the parameters to suit your specific needs.

  • Clean and assemble the unit. Make sure all pieces are cleaned and sterilized using an alcohol solution.
  • Connect the chiller to the condenser and set it to 0C (32F). Always fill a rotovap condenser from the top down (chiller output to top of condenser, chiller input to bottom of condenser).
  • Connect the vacuum pump to the cold trap and connect the cold trap to a vacuum port on rotovap.
  • Turn on the heat bath and set it to 40C (113F).
  • Once the heat bath, chiller, and cold trap have reached desired temperatures, turn on rotovap motor and set the speed to approximately 100 RPM (does not have to be precise).
  • Start the vacuum pump and allow the vacuum to pull down for a few minutes before injection.
  • Once the vacuum has been pulled to a sufficient level (does not have to be precise but should be below 100 Torr), using the injection valve, very slowly inject approximately 500 mL of solution into
  • the evaporating flask and then close the valve. Allow this small amount to begin evaporating. You may see the chiller begin to rise in temperature, this is called ”œpriming” the rotovap.
  • Once the temperature stops rising or all liquid is almost completely evaporated, open the injection valve again very slowly so that a small amount of liquid begins to enter the evaporating
  • flask. Do not close the injection valve this time but continue to allow the solution to enter the evaporating flask.
  • At this point, you must try to match the input speed to the output speed. What this means is that you should be injecting the same amount of liquid into the rotovap that is equal to the
  • amount of liquid dripping from the condenser into the receiving flask. You will know that the input speed and output speed are matched because the chiller will remain at a stable
  • temperature. If the chiller begins to rise, then you are injecting too much liquid. Dial back the valve until the chiller stabilizes.
  • Once everything is stabilized, you may walk away from the rotovap if necessary. Check every so often to make sure temperatures remain stable and evaporation continues efficiently.

***Note: All units are inspected for broken glass or parts before the unit is shipped. If the unit arrives damaged or glass is broken (this does not include minor imperfections or scuffs in glassware), the Customer MUST contact BVV™ within 3 days of delivery to file a claim and receive a replacement part. If the customer DOES NOT contact BVV™ within 3 days of delivery responsibility for replacement parts falls on the customer and they must pay for replacement pieces.***
***Note: This item will ship by freight only.***

***Glassware Safety Disclaimer: BVV™ is not responsible for the failure of glassware which must be inspected before and after every use because it may eventually develop imperfections or damage through normal usage, mishandling, and stress caused by temperature variations. If an imperfection or damage is noted while inspecting the glassware DO NOT use the glassware because it can fail to cause bodily harm or damage to the surrounding area.***


Correction of product information

If you notice any omissions or errors in the product information on this page, please use the correction request form below.

Correction Request Form

Customer ratings & reviews

4 out of 5
★★★★☆
135 ratings | 55 reviews
How item rating is calculated
View all reviews
5 stars
75% (101)
4 stars
8% (11)
3 stars
4% (5)
2 stars
2% (3)
1 star
11% (15)
Sort by

There are currently no written reviews for this product.